Find 4000 Amp Air Circuit Breaker Acb, Circuit Breaker, Air Circuit Breaker on Industry Directory, Reliable Manufacturer/Supplier/Factory from China.

Inquiry Basket (0)
Home > Products > LV Electrical Components > Circuit Breaker > IEC,CE Approved 2000A acb air circuit breaker

IEC,CE Approved 2000A acb air circuit breaker

Product Description

Product Description Product Overview GSW1 series universal circuit breakers(abbreviated circuit breakers as follow) could be suited for distribution net including frequency:50Hz、rated working voltage:400V、690V、rated current:200~6300A;and used for assigning the electrical energy and the protection line and the power equipment exempting such as overloaded,undervoltage,short-circuits,and single-phase earth harm,The circuit breaker has the intellectualized protection function, the selective protection is precise, which can enhance the power supply the reliability,and avoid the nonessential power cut,Compact structure、small volume and high Breaking Capacity.The seal contact system establishing zero overflash,The intelligent controller has test、load monitoring、great information display、real-time programming and communication function, which might establish perfect three sections or four section of protections Product feature Whole specifications,five frame current rated current from 200A to 6300 A GSW1-1600 universal Circuit Breaker △ the min dimensions:width:254mm volume:254mm(W)×329.5mm(H)×254mm(D) △ high breaking ability Icu=65kA,Ics=Icw=55kA GSW1-6300 universal circuit breaker △ the max current:to 6300A △ high breaking ability Icu=120kA,Ics=Icw=100kA ■ Reliable operation in the harsh conditions of high and low temperature Low-temperature: -40℃:storage,-25℃:work High-temperature:+70℃:storage、work ■ Resistance to impact and vibration Acceleration of impact:12g Acceleration of vibration:0.5g ■ Work in wide-voltage:AC/DC80~280V ■ Used as Switch-disconnectors、load-switch Applied environment △ Ambient temperature:-5℃~+40℃ average temperature in 24 hours ≤+35℃ △ Relative humidity No exceeding 50% at the maximum ambient temperature of 40℃ .With lower temperature ,higher humidity would be permitted, for instance:with temperature 20℃,the humidity can exceed 90%. Take the special measure to the dews on the surface, which would appear due to temperature change. △ Pollution protection:3grade △ Installation categories IV for the major circuit and III for auxiliary circuit except undervoltage release and primary circuit of transformers,whose installing categories is IV △ The breaker should be installed vertically,andvertical bank angle shall not exceed 5°
Product Parameters
Type
GSW1-1600
GSW1-2000
GSW1-3200
GSW1-4000
GSW1-6300
Pole Number
3P,4P,3P+N
3P,4P,3P+N
3P,4P,3P+N
3P,4P,3P+N
3P,4P,3P+N
Rated Current
200,400,630,800,1000,1250,1600
630,800,1000,1250,1600,2000
2000,2500,3200
4000
4000,5000,6300
Rated worlking Voltage Ue(V)
AC400,690V,50Hz
Rated Insulation Voltage Ui(V)
AC1000V,50Hz
Rated impulse Withstand Voltage Uimp(kV)
12
Limiting Short-circuit Breaking Capacity Icu(kA)
AC3500V,1min50Hz
Operation Short-circuit Breaking Capacity Ics(kA)
400V
65
80
100
100
120
690V
35
50
65
65
75
Rating Making Capacity of short circuit Icm
400V
55
50
65
65
100
690V
35
50
50
50
65
Rating Stand Current For Short-time(1s)Icw
400V
143
176
220
220
264
690V
73.5
105
143
143
165
Rated residual Working Current
400V
55
50
65
65
100
690V
35
50
65
50
65

Contact us if you need more details on 4000 Amp Air Circuit Breaker Acb. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Circuit Breaker、Air Circuit Breaker. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : LV Electrical Components > Circuit Breaker

Email to this supplier
  • *Subject:
  • To:

  • *Messages:
    Your message must be between 20-8000 characters